3-phase hybrid inverter with up to 4 MPP trackers and 1 battery connection
Description
10 kW hybrid inverter, 3-phase
Up to 4 mpp tracker + 1 battery connection
Substitute current capable in connection with backup power box
Compatible with common high-voltage batteries
WiFi and LAN
Easy installation
Features
Product features
- Flexible and expandable
- Simple installation
- Suitable for outdoor installation
Downloads
- SolBrid certificate CE-Erklärung · pdf · 1.373 MB
- SolBrid certificate NA-Schutz · pdf · 0.482 MB
- SolBrid certificate Einheitenzertifikat · pdf · 0.566 MB
- SolBrid certificate Vaatimustenmukaisuustodistus · pdf · 0.541 MB
- SolBrid certificate Certificate of compliance · pdf · 0.424 MB
- SolBrid certificate Samsvarssertifikat · pdf · 0.544 MB
- SolBrid certificate Unbedenklichkeitsbescheinigung · pdf · 0.552 MB
- SolBrid certificate Unbedenklichkeitsbescheinigung · pdf · 0.550 MB
- SolBrid certificate Certificate of compliance · pdf · 0.505 MB
- SolBrid certificate Intyg om överensstämmelse · pdf · 0.536 MB
- SolBrid certificate Einheitenzertifikat · pdf · 0.566 MB
- SolBrid certificate Zertifikat für den NA-Schutz · pdf · 0.482 MB
- SolBrid product pic · png, 300 DPI, high quality · 42.287 MB
- SolBrid product pic · png, 72 DPI, web quality · 42.287 MB
- SolBrid product pic · png, 300 DPI, high quality · 23.928 MB
- SolBrid product pic · png, 72 DPI, web quality · 23.928 MB
- SolBrid product pic · png, 300 DPI, high quality · 24.513 MB
- SolBrid product pic · png, 72 DPI, web quality · 24.513 MB
Technical data
SolBrid 10-3-2 | SolBrid 10-3-4 | |
---|---|---|
DC input side (PV generator) | ||
Maximum input voltage | 1000 V | |
MPP-voltage range in mains parallel operation | 85 V … 850 V | |
MPP-voltage range for zero-voltage systems | 85 V … 700 V | |
Operating voltage range at rated power (1 MPP) | 670 V … 850 V | |
Operating voltage range at rated power (2 MPP) | 340 V … 850 V | |
Operating voltage range at rated power (4 MPP) | 180 V … 850 V | |
Number of MPP tracker | 2 | 4 |
Max. PV input current per PV input | 15 ADC | |
Maximum short circuit current | 18 A | |
Maximum input power at maximum active output power | 10300 W | |
Max. connectable pv-output (total) | 12 000 W, total PV 1 + 2 = 12 000 W max. | 15 000 W, total PV 1 + 2 + 3 + 4 = max. 15000 W, total PV 1 + 2 = max. 12 000 W, total PV 3 + 4 = max. 12 000 W |
Max. connectable pv-output (per channel) | 9000 W per PV-input | |
AC output side (Grid connection) | ||
Grid voltage | 3x 185 V … 276 V | |
Rated grid voltage | 3x 230 V | |
Rated output current | 14.49 A | |
Maximum output current | 16.0 A | |
Maximum active power (cos phi = 1) | 10000 W | |
Max. apparent performance with cos phi = 1 | 10000 VA | |
Rated power | 10000 W | |
Rated frequency | 50 Hz | |
Frequency range | 45 Hz … 55 Hz | |
Night-time power loss | < 6 W | |
Feeding phases | three-phase | |
Power factor cos phi | 0.8 capacitive … 0.8 inductive | |
Highest output fault current | 16 A | |
Battery connection | ||
Number of battery inputs | 1 | |
Maximum input voltage | 1000 VDC | |
Operating Voltage Range | 85 V - 700 V | |
Operating voltage range at rated power | 400 V … 700 V | |
Max. input current | 25 ADC | |
Max. input power with max. AC output active power | 10 300 W | |
Characterisation of the operating performance | ||
Max. efficiency | 97.5 % | |
European efficiency | 97.1 % | |
MPP efficiency | > 99.7 % (static), > 99 % (dynamic) | |
Power derating at full power from | 40 °C (Tamb) | |
Safety | ||
Isolation principle | no galvanic isolation, transformerless | |
Grid monitoring | yes, integrated | |
Residual current monitoring | yes, integrated (The design of the inverter prevents it from causing DC leakage current) | |
Compatibility with external residual current devices | RCD type A | |
Protection class | protection class I (protectiv) | |
Operating conditions | ||
Area of application | outdoors & indoors | |
Climate protection class as per IEC 60721-3-4 | 4K4H | |
Altitude | Max. 2 000 m about NN | |
Ambient temperature | -25 °C … +60 °C | |
Relative humidity | 0 % … 100 %, condensing | |
Noise emission (typical) | 31 dBA | |
Fitting and construction | ||
Degree of protection | IP 65 | |
Overvoltage category | III (AC), II (PV / Bat) | |
AC output side connection | Wieland 5-pole | |
Dimensions (X x Y x Z) | 700 x 500 x 181 mm | |
Weight | 29.0 kg | |
Communication interface | LAN-connection (RJ45), WiFi, RS485 A (RJ45), RS485 B (RJ45) battery interface, RS485 C (RJ45) Gridswitch (mains isolating meter) and approved energy meters | |
Integrated DC circuit breaker | yes, compliant with VDE 0100-712 | |
Cooling principle | Convection cooling on the outside, temperature-controlled fan on the inside, variable speed, internally dust-protected | |